{{ $t('shop.all.spaetbestellservice.hinweis') }}
Permission |
RCM mark, c UL us - Listed (OL) |
CE certificate (see declaration of conformity) |
acc. to EU-EMV Directive, acc. to EU-RoHS Directive |
KC-mark | KC-EMV |
Certified awarding point | UL E322346 |
Material information | RoHs compliant |
Measured parameter |
Mass flow, Volume flow rate |
Flow direction | Uni-directional |
Measurement principle | Thermic |
Measurement process | Heat Transfer |
Flow measurement range starting value [l/min] | 0,200 |
Flow measurement range end value [l/min] | 10,0 |
Operating pressure [bar] | -0.9 to 10 |
Operating medium |
Druckluft nach ISO 8573-1:2010 [6:4:4], Stickstoff, Argon |
Medium temperature [°C] | 0 to 50 |
ambient temperature [°C] | 0 to 50 |
Nominal temperature [°C] | 23 |
Accuracy flow value | ± (2% o.m.v. + 1% FS) |
Repeatability null point in ± %FS [%FS] | 0,2 |
Repeatability clamp in ± %FS [%FS] | 0,8 |
Temperature coefficient clamp in ± %FS/K | type 0,15%FS/K |
Pressure dependency clamp in ± %FS/bar [%FS/b.] | 1 |
Control output | 2 x PNP or 2 x NPN switchable |
Switch function |
Window comparator, Threshold comparator, Auto difference monitoring |
Switching element function | Opener/closer switchable |
Max. output current [mA] | 100 |
Analogue output |
0 - 10 V, 4 - 20 mA, 1 - 5 V |
Flow characteristic curve starting value [l/min] | 0 |
Flow characteristic curve end value [l/min] | 10,0 |
Max. load resistance current output [Ohm] | 500 |
Min. load resistance voltage output [kOhm] | 20 |
Short circuit resistance | yes |
Overload resistant | Available |
Report | IO-Link |
IO-Link, report | Device V 1.1 |
IO-Link, profile | Smart sensor profile |
IO-Link, function classes |
Teach channel, Diagnosis, Identification, Binary data channel (BDC), Process data variables (PDV) |
IO-Link, communication mode | COM2 (38.4 kBaud) |
IO-Link, SIO mode support | yes |
IO-Link, port type | A |
IO-Link, process data width IN | 3 Bytes |
IO-Link, process data contents IN |
1 bit BDC (Volume monitoring), 14 bit PDV (Flow measurement), 2 bit BDC (Flow monitoring) |
IO-Link, service data unit IN | 32 bit Volumen-/Massemesswert |
IO-Link, minimum cycle time | 4 ms |
IO-Link, data memory needed [Byte] | < 0,5 kB |
Operating voltage range DC [V] | 22 to 26 |
Empty run current [mA] | <= 25 mA |
Reverse polarity protection | for all electrical connections |
Electrical connection 1, connection type | Plug |
Electrical connection 1, connection technology | M8x1 A coded to EN 61076-2-104 |
Electrical connection 1, number of pins / wires | 4 |
Fastening type | With Accessories |
installation position | arbitrary |
Pneumatic connection | For hose exterior diameter 6 mm |
Pneumatic connection, connection outlet | straight |
Product weight [g] | 60 |
Housing material | PA reinforced |
From medium contacting materials |
NBR, high-alloyed stainless steel, PA reinforced, Alu wrought alloy, anodised, Epoxy resin, Silicon, Silicon nitride |
Display type | Illuminating LCD Multiple |
Presentable unit(s) |
g, g/min, l, l/h, l/min, scft, scft/h, scft/min |
Setting options |
IO-Link, Teach-In, über Display und Tasten |
Tamper-proof fuse |
IO-Link, PIN code |
Protection category | IP40 |
Pressure drop [mbar] | < 5 mbar |
Protection class | III |
Corrosion resistant class KBK | 2 - moderate corrosion stress |
{{ $t('shop.all.gewicht') }} | 60 g / Pièce |
{{ $t('shop.all.gtin') }} | 4052568295523 |
{{ $t('shop.display.artikel.zollwarennummer') }} | 90268020 |
{{ $t('shop.all.hersteller') }} | Festo |