Design | For T-slot |
Based on standard | EN 60947-5-6 |
Permission | RCM mark |
CE certificate (see declaration of conformity) |
to EU EMC directive, to EU EX protection directive (ATEX) |
KC-mark | KC-EMV |
Special features | Oil resistant |
Material information |
halogen free, Copper and PTFE-free, RoHs compliant |
Measured parameter | Position |
Measurement principle | Magnetoresistive |
ambient temperature [°C] | -40 to 85 |
Repeatability [mm] | 0,2 |
Control output | NAMUR |
Switching element function | NAMUR |
Switch on time [ms] | < 1 ms |
Switch off time [ms] | < 1 ms |
Max. switching frequency [Hz] | 330 |
Residual current [mA] | 0.4 to 1 |
Rated operating voltage DC [V] | 8,2 |
Operating voltage range DC [V] | 7.5 to 18 |
Reverse polarity protection | for all electrical connections |
Electrical connection 1, connection type | cable |
Electrical connection 1, connection technology | Open end |
Electrical connection 1, number of pins / wires | 2 |
Connection outlet direction | along |
Test conditions line |
Bending radius strength to Festo standard, Test conditions on request |
Cable length [MTR] | 5,0 |
Line properties |
Robot friendly, Cable track capable |
Cable shield colour | blue |
Cable sleeve material | TPE-U(PUR) |
Insulation sleeve material | PP |
Fastening type |
Insertable from above into the slot, Permanently screwed |
Max. tightening torque [Nm] | 0,6 |
installation position | arbitrary |
Product weight [g] | 53,0 |
Housing colour | black |
Housing material |
High-alloyed stainless steels, PA reinforced |
Switching status indicator | LED yellow |
Ambient temperature for moving cable placements [°C] | -20 to 85 |
Protection category |
IP65, IP68 |
Wire ends | Wire end sleeve |
ATEX gas category | II 1G |
Ex ignition protection type gas | Ex ia IIC T4...T6 Ga |
ATEX dust category | II 1D |
Ex ignition protection type dust | Ex ia IIIC T135°C Da |
Ex protection approval outside of the EU |
EPL Da (BR), EPL Da (IEC-EX), EPL Ga (BR), EPL Ga (IEC-EX) |
Ex ambient temperature |
T4: -20°C <= Ta <= +85°C, T6: -20°C <= Ta <= +45°C, T4, For permanent cable placement: -40°C <= Ta <= +85°C, T6, For permanent cable placement: -40°C <= Ta <= +45°C |
Max. input voltage [V] | 28 |
Max. input current [A] | 0,25 |
Max. input power |
T4: 350 mW, T6: 72 mW |
Effective inductivity | 30 µH |
Effective capacity | 79 nF |
Certified awarding point |
DNV 17.0027 X, IECEx PTZ 18.0008X, PTZ 16 ATEX 0010 X |
residual ripple | 10 % |
{{ $t('shop.all.gewicht') }} | 53,0 g / Pièce |
{{ $t('shop.all.gtin') }} | 4052568262952 |
{{ $t('shop.display.artikel.zollwarennummer') }} | 85365019 |
{{ $t('shop.all.hersteller') }} | Festo |