{{ $t('shop.all.spaetbestellservice.hinweis') }}
Fastening type | Assembly plate, screwed |
installation position |
Open convection, vertical |
Product weight [g] | 1.300 |
Display | LED green / yellow / red |
Operating element | Optional: Control unit CDSB |
Complies to standard |
EN 61800-3, EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1 |
Based on standard |
EN 50581, EN 60204-1, EN 61508-1, EN 61508-2, EN 61508-3, EN 61508-4, EN 61508-5, EN 61508-6, EN 61508-7, EN 61800-2, EN 62061 |
Permission |
RCM Mark, TÜV, c UL us - Listed (OL) |
KC-mark | KC-EMV |
CE certificate (see declaration of conformity) |
acc. to EU-EMV Directive, acc. to EU Machine Directive, acc. to EU Low voltage Directive, acc. to EU-RoHS Directive |
Certified awarding point |
UL E331130, TÜV Rheinland 01/205/5640.00/18 |
Bearing temperature [°C] | -25 to 55 |
ambient temperature [°C] | 0 to 50 |
Information about ambient temperature | Oberhalb der Umgebungstemperatur von 40 °C ist eine Leistungsreduktion von 3 %/°C einzuhalten. |
UL - ambient temperature [°C] | 0 to 40 |
Relative humidity |
5 - 90 %, Not condensing |
Max. setup height [MTR] | 2.000 |
Information about max. setup height | From 1000 m power reduction by 1% per 100 m |
Protection category | IP20 |
Protection class | I |
Over-voltage category | III |
Degree of contamination | 2 |
Surge voltage strength [kV] | 6 |
Material information |
LABS containing materials included, RoHs compliant |
Phase nominal operating voltage | 1-phase |
Nominal operating voltage AC [V] | 230 |
Permitted voltage oscillations | -20 % / +15 % |
Input voltage range AC [V] | 100 to 230 |
Network frequency [Hz] | 48 to 62 |
Nominal current load supply [A] | 2,8 |
Peak current load supply [A] | 8,4 |
Active PFC | no |
Network filter | integrated |
System voltage acc. to EN 61800-5-1 [V] | 300 |
Max. short circuit resistance of the network [kA] | 100 |
Network forms |
TT, TN, IT |
Nominal voltage load supply DC [V] | 320 |
Permitted range load supply | -20 %/+15 % |
Max. intermediate circuit voltage DC [V] | 395 |
Braking resistance, integrated [Ohm] | 100 |
Impulse power braking resistance [kVA] | 1,6 |
Braking resistance pulse energy [Ws] | 230 |
Braking resistance nominal performance (IEC) [W] | 23 |
Braking resistance, external [Ohm] | 100 to 160 |
Max. continuous power of the external braking resistance (IEC) [W] | 180 |
Nominal voltage logic supply DC [V] | 24 |
Permitted range logic voltage | ± 20 % |
Power input logic supply without parking brake [A] | 0,5 |
Power input logic supply with parking brake [A] | 1,5 |
Max. power input for logic supply, parking brake and IO [A] | 2,3 |
Output voltage range AC | 3x (0 – Input) V |
Nominal current per phase, effective [A] | 2 |
Peak current per phase, effective [A] | 6 |
Max. peak current duration [s] | 2 |
Nominal performance controller [VA] | 350 |
Peak performance [VA] | 1.000 |
Output frequency [Hz] | 0 to 599 |
Max. length motor line without ext. network filter [MTR] | 25 |
Max. output current holding brake [A] | 1 |
Max. voltage drop from logic supply to brake output [V] | 0,8 |
Quantity of inputs for motor temperature sensor | 1 |
Operating mode controller |
Autotuning, P position controller, PI-speed controller, Setup mode, Interpolated operation via fieldbus, Cascade control, PI current controller for F or M, Profile operation with set and direct operation, Reference run, Synchronous operating modes |
Operating mode |
2x Input-Capture (x, v, F), 2x Output-Trigger (x, v, F), 1x SYNC-interface for encoder emulation or encoder input, 2x position sensor input, Sampling rate 16 kHz, Real time data recording, Field oriented control, Position resolution 24 bit/rev, PWM with 8 or 16 KHz, Vector modulation with 3rd harmonic |
Ethernet interface, function | Parameterising and commissioning |
Ethernet interface, report | TCP/IP |
Fieldbus interface, report |
PROFINET IRT, PROFINET RT |
Fieldbus coupling | PROFINET |
Communication profile |
PROFIdrive, PROFIenergy |
Process coupling |
AC1: Adj.-Speed Drives, AC4: Synchr. Servo Application, AC3: Drive w. Positioning Func |
Fieldbus interface, transfer rate | 100 Mbit/s |
Fieldbus interface, connection type | 2x socket |
Fieldbus interface, connection technology | RJ45 |
Encoder interface, function |
ENDAT 2.1 sensor, ENDAT 2.2 sensor, Hiperface sensor, Incremental sensor, Nikon, SIN/COS sensor |
Encoder interface 2, function |
Incremental sensor, SIN/COS sensor |
Synchronous interface, function |
Zählsignale CW/CCW, Encoder-Eingang A/B/Z, Encoderemulation A/B/Z, Puls-Richtungssignale CLK/DIR |
Encoder output interface, properties |
max. 16384 ppr, 1 MHz maximale Ausgangsfrequenz |
Encoder input interface, properties |
max. 16384 ppr, 1 MHz maximale Ausgangsfrequenz |
Quantity digital logic inputs | 12 |
Switching logic inputs | PNP (Positive switching) |
Properties logic inputs |
partially freely configurable, not galvanically separated, partially safety inputs |
Logic input specification | depending on IEC 61131-2, type 3 |
Work area logic input [V] | -3 bis 30 |
Quantity of high-speed logic inputs | 2 |
Time resolution of high-speed logic inputs [µs] | 1 |
Quantity digital logic outputs 24 V DC | 6 |
Switching logic outputs | PNP (Positive switching) |
Properties digital logic outputs |
partially freely configurable, not galvanically separated, partially diagnosis outputs |
Max. current digital logic outputs [mA] | 20 |
Quantity of high-speed switch outputs | 2 |
Time resolution of high-speed switch outputs [µs] | 1 |
Quantity of zero potential switch outputs | 1 |
Max. current of the zero potential switch outputs [mA] | 50 |
Quantity analogue target value inputs | 1 |
Properties target value inputs |
Differential inputs, Configurable for rotational speed, Configurable for current/force |
Work area target value input | ± 10 V |
Work area analogue inputs | ± 10 V |
Impedance target value input [kOhm] | 70 |
Safety function |
Safe switched off torque (STO), Safe braking controls (SBC), Safe stop 1 (SS1) |
Safety Integrity Level (SIL) |
Safe switched off torque (STO) / SIL 3 / SILCL 3, Safe braking controls (SBC) / SIL 3 / SILCL 3 |
Performance Level (PL) |
Safe switched off torque (STO) / Category 4, Performance Level e, Safe braking controls (SBC) / Category 3, Performance Level e |
Diagnose degree of coverage [%] | 97 |
SFF Safe Failure Fraction [%] | 99 |
Hardware error tolerance | 1 |
Quantity of safe 2-pin inputs | 2 |
Quantity of diagnosis outputs | 2 |
{{ $t('shop.all.gewicht') }} | 1.300 g / Pièce |
{{ $t('shop.all.gtin') }} | 4052568597290 |
{{ $t('shop.display.artikel.zollwarennummer') }} | 85044085 |
{{ $t('shop.all.hersteller') }} | Festo |
{{ $t('shop.all.spaetbestellservice.hinweis') }}
{{ $t('shop.all.wochenendversand.hinweis') }}
Une erreur s'est produite. Veuillez recharger la page et réessayer.