Polnilni ventili (zagonski ventili) - Futura, do 10000 l/min
{{ bild.Beschreibung }}
{{ bildGross.Beschreibung }}
{{ bildGross.Beschreibung }}
{{ bildGross.Beschreibung }}
Materials:
Body: PA 66 GF60, cover: POM, seals: NBR
Temperature range:
-10 do +50 °C
Media:
Oiled and unoiled compressed air, neutral gasses
Advantages:
•easy assembly of single components within a model series using coupling kits
Input pressure:
2.5 - 16 bar (model series 0: 2.5 - 12 bar)
Function:
The machines are allowed to breathe gradually via an orifice. Once the pressure reaches a value of approx. 50% of the input pressure and the cylinders have slowly moved into their initial position, the start-up valve switches over to maximum throughway. The speed of the pressure build-up can be controlled using an adjustment screw.
ATEX:
Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU (not model series 0)
Warning:
Shut-off valves (e.g. ball valves) must be installed before the filler valve!
{{ $t('shop.all.dokumente') }}:
Catalogue page Atlas 9 (Page 574) atlas9_seiten/574.pdf
Dokumentacijo doku/futura.pdf
Dokumentacijo: Decision aid for selection of air units doku/entscheidungshilfe_wartungsgeraete.pdf