Data sheet

Multi stage ejectors to 90% vacuum, G 1-1/2", to 2100 l/min
{{ $t('shop.all.artikelnummer') }}:
VILP 32
Example illustration
{{ $t('shop.display.artikel.beschreibung_headline') }}
Materials:
Body: anodised aluminium, nozzles: brass, seal: neoprene
Temperature range:
-20 to +80 °C
Operating pressure:
1 to 7 bar (optimum 4 - 6 bar)
Pressure gauge connection:
G 1/4"
Advantages:
•high vacuum,
•higher flow,
•low cost,
•maintenance free,
•high vacuum, ideal for vacuum packaging or large forces with small suction caps with a simultaneous high vacuum flow
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Suction performance [l/min] 2100
Thread Supply air G 3/8"
Thread vacuum G 1-1/2"
Thread exhaust air G 1-1/2"
Air consumption* [l/min] 700
Silencer** FFSD 112
Vacuum meter MW -163
L [mm] 250
B [mm] 97
H [mm] 65
Evacuation time down to 10 % vacuum [s/l] 0,00300
Evacuation time down to 20 % vacuum [s/l] 0,00500
Evacuation time down to 30 % vacuum [s/l] 0,010
Evacuation time down to 40 % vacuum [s/l] 0,0300
Evacuation time down to 50 % vacuum [s/l] 0,0500
Evacuation time down to 60 % vacuum [s/l] 0,080
Evacuation time down to 70 % vacuum [s/l] 0,130
Evacuation time down to 80 % vacuum [s/l] 0,23
Evacuation time down to 90 % vacuum [s/l] 0,850
Flow at 0% vacuum [l/min] 2.100
Flow at 10% vacuum [l/min] 1.500
Flow at 20% vacuum [l/min] 980
Flow at 30% vacuum [l/min] 520
Flow at 40% vacuum [l/min] 360
Flow at 50% vacuum [l/min] 300
Flow at 60% vacuum [l/min] 215
Flow at 70% vacuum [l/min] 140
Flow at 80% vacuum [l/min] 84
Further information:
{{ $t('shop.all.gewicht') }} 2,6 kg / pcs
{{ $t('shop.all.gtin') }} 4050571719630
{{ $t('shop.display.artikel.zollwarennummer') }} 84141089
{{ $t('shop.display.artikel.rohskonform') }} {{ $t('shop.all.ja') }}
Figure
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Our products arid goods are generally only intended for industrial and commercial uses.
As of: 19.12.2025