Data sheet

STANDARD Microfilter (sub-microfilter), G 3/4", Standard 5
{{ $t('shop.all.artikelnummer') }}:
DFX 54
Example illustration
{{ $t('shop.display.artikel.beschreibung_headline') }}
Application:
Sub-microfilters are used where high demands are placed on the purity of the compressed air. Micro-particles (> 0.01 µm) and oil mist are separated here. We recommend connecting an upstream microfilter to increase the service life.
Materials:
Body: Zinc die-casting Z410, condensate container: Polycarbonate, filter insert: Borosilicate microfibre fleece
Temperature range:
0°C to max. +50°C (metal bowl up to max. +90°C)
Dust removal:
> 0,01 µm (99,999 %)
Residual oil content:
0,01 mg/m³
Erreichbare Druckluftqualität (ISO 8573-1):
[1:4:2] (ohne Kältetrockner: [1:7:2])
Input pressure:
1.5 - 16 bar (with metal bowl 0 - 25 bar)
Condensate draining:
Semi-automatic** (metal container: manual)
Media:
Compressed air, neutral gases
Optional:
Version with protection cage (not series 5)-S, version with metal tank with manual drain (0 - 25 bar) -M
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Version Microfilter (sub-microfilter)
Model series Standard 5
Thread G 3/4"
Flow* [l/min] 4350
Container design Plastic container
Condensate drain Semi-automatic
Mounting brackets ZW DFX 50
Replacement filter 0,01 µm FILTER DFX 50
input pressure [bar] 1,5 - 16
Temperature range [°C] 0 to +50
Max. condensate amount [cm³] 48
H [mm] 242
H1 [mm] 206
L [mm] 134 (Ø 133)
Further information:
{{ $t('shop.all.gewicht') }} 2,4 kg / pcs
{{ $t('shop.all.gtin') }} 4050571248598
{{ $t('shop.display.artikel.zollwarennummer') }} 84213925
{{ $t('shop.display.artikel.rohskonform') }} {{ $t('shop.all.ja') }}
Figure
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Our products arid goods are generally only intended for industrial and commercial uses.
As of: 19.12.2025