Data sheet

CTEU-DN (570039) Bus node
{{ $t('shop.all.artikelnummer') }}:
OT-FESTO033782
Example illustration
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Dimensions W x L x H 40 mm x 91 mm x 50 mm
Pitch dimension [mm] 40
Fastening type auf Elektrik-Anschaltung,
auf Elektrik-Anschlussplatte
Report DeviceNet
Fieldbus interface CAN bus
Fieldbus interface, report DeviceNet
Fieldbus interface, connection type Plug
Fieldbus interface, connection technology Sub-D
Fieldbus interface, number of pins / wires 9
LABS (PWIS) conformity optionale Anschlusstechnik mit Zubehör:,
optionale Anschlusstechnik mit Zubehör: Micro Style (Stecker/Dose M12x1 A-codiert, 5-polig, Schutzart IP65) Open Style (Klemmleiste, 5-polig, Schutzart IP20),
Open Style (Schraubklemme, 5-polig, Schutzart IP20)
Fieldbus interface, galvanically separated yes
UKCA marking (see declaration of conformity) 125 kbit/s,
250 kbit/s,
500 kbit/s
Internal cycle time 1 ms per 1 byte user data
Max. address volume inputs [Byte] 8
Material information [Byte] 8
Voltage supply, function Electronics and load
Voltage supply, connection type Plug
Voltage supply, connection technology M12x1 B coded to EN 61076-2-101
Voltage supply, number of poles/wires 5
Diagnosis Unterspannung,
Kommunikationsfehler,
Systemdiagnose
Parameterising Diagnoseverhalten,
Failsafe- und Idle Reaktion
Fieldbus interface Quick connect,
System status can be shown from process dat,
- Acyclical data access via "Explicit message"
Operating element DIL switch
Fieldbus interface, function PS: Operating voltage electronics and load supply,
X1: System status module I port 1,
X2: System status module I port 2
LED display bus specific IO: I/O status,
MNS: Network status
Operating voltage range DC [V] 18 to 30
Fieldbus interface, connection pattern [V] 24
Intrinsic power input at operating voltage Type 65 mA
Fieldbus interface, galvanically separated [A] 4
Permission RCM mark,
c UL us - Listed (OL)
Max. address volume, inputs KC-EMV
Max. address volume, outputs to EU EMC directive
Corrosion resistant class KBK 2 - moderate corrosion stress
Bearing temperature [°C] -20 to 70
Protection category IP65,
IP67
Information about protection category in assembled condition,
unused connection closed
ambient temperature [°C] -5 to 50
Housing material PA,
PC
Power supply, connection pattern LABS containing materials included,
RoHs compliant
Intern power consumption nominal operating voltage EDS file
Further information:
{{ $t('shop.all.gewicht') }} 100 g / pcs
{{ $t('shop.all.gtin') }} 4052568216498
{{ $t('shop.display.artikel.zollwarennummer') }} 85176200
{{ $t('shop.all.hersteller') }} Festo
Figure
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Our products arid goods are generally only intended for industrial and commercial uses.
As of: 19.12.2025