Data sheet

CTEU-CO (570038) Bus node
{{ $t('shop.all.artikelnummer') }}:
OT-FESTO033781
Example illustration
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Dimensions W x L x H 40 mm x 91 mm x 50 mm
Pitch dimension [mm] 40
Fastening type auf Elektrik-Anschaltung,
auf Elektrik-Anschlussplatte
Report CANopen
Fieldbus interface CAN bus
Fieldbus interface, report CANopen
Fieldbus interface, connection type Plug
Fieldbus interface, connection technology Sub-D
Fieldbus interface, number of pins / wires 9
LABS (PWIS) conformity optionale Anschlusstechnik mit Zubehör:,
optionale Anschlusstechnik mit Zubehör: Micro Style (Stecker/Dose M12x1 A-codiert, 5-polig, Schutzart IP65) Open Style (Klemmleiste, 5-polig, Schutzart IP20),
Open Style (Schraubklemme, 5-polig, Schutzart IP20)
Fieldbus interface, galvanically separated yes
UKCA marking (see declaration of conformity) 125 kbit/s,
250 kbit/s,
500 kbit/s,
1000 kbit/s
Internal cycle time 1 ms per 1 byte user data
Max. address volume inputs [Byte] 8
Material information [Byte] 8
Voltage supply, function Electronics and load
Voltage supply, connection type Plug
Voltage supply, connection technology M12x1 B coded to EN 61076-2-101
Voltage supply, number of poles/wires 5
Diagnosis Unterspannung,
Kommunikationsfehler,
Systemdiagnose
Parameterising Failsafe-Reaktion,
Diagnoseverhalten
Fieldbus interface Emergency message,
- Acyclical data access via "SDO"
Operating element DIL switch
Fieldbus interface, function PS: Operating voltage electronics and load supply,
X1: System status module I port 1,
X2: System status module I port 2
LED display bus specific IO: I/O status,
MNS: Network status
Operating voltage range DC [V] 18 to 30
Fieldbus interface, connection pattern [V] 24
Intrinsic power input at operating voltage Type 65 mA
Fieldbus interface, galvanically separated [A] 4
Permission RCM mark,
c UL us - Listed (OL)
Max. address volume, inputs KC-EMV
Max. address volume, outputs to EU EMC directive
Corrosion resistant class KBK 2 - moderate corrosion stress
Bearing temperature [°C] -20 to 70
Protection category IP65,
IP67
Information about protection category in assembled condition,
unused connection closed
ambient temperature [°C] -5 to 50
Housing material PA
Power supply, connection pattern LABS containing materials included,
RoHs compliant
Intern power consumption nominal operating voltage EDS file
Fieldbus interface 2, connection pattern max. expandable to 16 byte
Information about outputs max. expandable to 16 byte
Further information:
{{ $t('shop.all.gewicht') }} 95 g / pcs
{{ $t('shop.all.gtin') }} 4052568216481
{{ $t('shop.display.artikel.zollwarennummer') }} 85176200
{{ $t('shop.all.hersteller') }} Festo
Figure
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Our products arid goods are generally only intended for industrial and commercial uses.
As of: 19.12.2025