Design | For T-slot |
Permission |
RCM mark, c UL us - Listed (OL) |
CE certificate (see declaration of conformity) | to EU EMC directive |
KC-mark | KC-EMV |
Material information |
halogen free, RoHs compliant |
Measured parameter | Position |
Measurement principle | Hall magnetic |
Recording range [µm] | 0 to 80000 |
ambient temperature [°C] | -25 to 70 |
Sampling interval type [ms] | 1 |
Max. movement speed [m/s] | 3 |
Resolution travel [mm] | 0,05 |
Repeatability [mm] | 0,1 |
Control output | PNP |
Switching element function | Opener/closer switchable |
Switch on time [ms] | < 2 ms |
Switch off time [ms] | < 2 ms |
Max. switching frequency [Hz] | 1.000 |
Max. output current [mA] | 100 |
Max. switching capacity DC [W] | 2,7 |
Voltage drop [V] | 2,5 |
Analogue output | 4 - 20 mA |
Sensitivity current output [mA/mm] | 0,200 |
Linearity error typical in ± mm | ±0.25 mm |
Max. load resistance current output [Ohm] | 500 |
Short circuit resistance | yes |
Overload resistant | Available |
Report |
I-port, IO-Link |
IO-Link, report | Device V 1.1 |
IO-Link, profile | Smart sensor profile |
IO-Link, function classes |
Teach channel, Diagnosis, Identification, Binary data channel (BDC), Process data variables (PDV) |
IO-Link, communication mode | COM3 (230.4 kBaud) |
IO-Link, SIO mode support | yes |
IO-Link, port type | A |
IO-Link, process data width IN | 2 Bytes |
IO-Link, process data contents IN |
12 bit PDV (position measurement), 4 bit BDC (position monitoring) |
IO-Link, minimum cycle time | 1 ms |
Operating voltage range DC [V] | 15 to 30 |
residual ripple | 10 % |
Reverse polarity protection | for all electrical connections |
Electrical connection 1, connection type | Cable with plug |
Electrical connection 1, connection technology | M8x1 A coded to EN 61076-2-104 |
Electrical connection 1, number of pins / wires | 4 |
Electrical connection 1, fastening type | Screw lock |
Connection outlet direction | along |
Plug contacts material |
Copper allow, Gold plated |
Test conditions line |
Bending radius strength to Festo standard, Cable track: 5 million cycles, bending radius 28 mm, Torsional strength > 300,000 cycles, ±270°/0.1 m |
Cable length [MTR] | 0,3 |
Line properties | Cable track+robot |
Cable shield colour | Grey |
Cable sleeve material | TPE-U(PUR) |
Fastening type |
Insertable from above into the slot, Permanently screwed |
installation position | arbitrary |
Product weight [g] | 23 |
Housing material |
High-alloyed stainless steels, PA reinforced, brass nickel-plated, Polyester |
Locking nut material | Nickel-plated brass |
Foil material | Polyester |
Operation-readiness display | LED green |
Switching status indicator | LED yellow |
Status display | LED red |
Setting options |
IO-Link, Button |
Ambient temperature for moving cable placements [°C] | -20 to 70 |
Protection category |
IP65, IP68 |
{{ $t('shop.all.gewicht') }} | 23 g / Kos |
{{ $t('shop.all.gtin') }} | 4052568238087 |
{{ $t('shop.display.artikel.zollwarennummer') }} | 90318020 |
{{ $t('shop.all.hersteller') }} | Festo |