{{ $t('shop.all.spaetbestellservice.hinweis') }}
Valve function | 3/2 closed monostable |
Actuation type | Electrical |
Build.width [mm] | 30 |
Normal nominal flow [l/min] | 50 |
Operating pressure [bar] | 1 to 16 |
Construction set up | Plate seat |
Reset mode | Mechanical spring |
Protection category | IP65 |
Nominal width [mm] | 1,3 |
Pitch dimension [mm] | 42 |
Exhaust function | Cannot be throttled |
Based on standard | ISO 15218 |
Sealing principle | Soft |
installation position | arbitrary |
Complies to standard | ISO 15218 |
Hand assist actuation | tentative |
Control type | Direct |
Flow direction | Not reversible |
Überdeckung | negative Überdeckung |
Shifting time off [ms] | 9 |
Shifting time on [ms] | 11 |
Power-on time | 100 % |
Coil characteristic value |
110 V AC: 50 Hz, pull-in power 14.5 VA, holding power 10.5 VA, 110 V AC: 60 Hz, pull-in power 12.0 VA, holding power 7.6 VA |
Permitted voltage oscillations | ± 10 % |
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
Information about operating and control medium | Oiled operation possible (required in further operations) |
Corrosion resistant class KBK | 2 - moderate corrosion stress |
Medium temperature [°C] | -15 to 80 |
ambient temperature [°C] | -15 to 50 |
Product weight [g] | 140 |
Electrical connection |
Wiring diagram Form A acc. to EN 175301-803, acc. to DIN EN 175301-803 |
Fastening type |
on connection plate, With throughway bores |
Pneumatic connection 1 | Connection plate |
Pneumatic connection 2 | Connection plate |
Pneumatic connection 3 | Not recorded |
Material information | RoHs compliant |
Seals material | FPM |
CE certificate (see declaration of conformity) | to EU low voltage directive |
Permitted frequency oscillations | ± 10 % |
{{ $t('shop.all.gewicht') }} | 140 g / Pz. |
{{ $t('shop.all.gtin') }} | 4052568068240 |
{{ $t('shop.display.artikel.zollwarennummer') }} | 84812090 |
{{ $t('shop.all.hersteller') }} | Festo |